Guard Houses & Shelters

 

65B.jpgEB 62.jpg13s Barrel Valut Transit Shlt STS730G-BV.jpg07b Info Booth Masonic STB58G-M.jpg

 

  Benefits Uses
..............
  • Permanent or Portable
  • Bullet Resistant
  • Pre-Fabricated
  • Steel or aluminum construction
  • Security
  • Control Rooms
  • Transit Shelters
  • Smoking Shelters

 

Sample Specifications for Aluminum Buildings

 

Frame: Provide snap together type structural framing of 6063-T6 aluminum alloy extrusions. Connections shall be fastened internally to framing systems using concealed mechanical fasteners or MIG welded where necessary. Members shall have a manufacturer’s standard Quaker Bronze, Austin White or Clear Anodized finish. Custom colors are available at additional cost.

Base/Floor: Finished floor of nonskid aluminum tread plate. Floor is mounted to 2” or 4” tube/channel steel base frame (depending on building size).

Lower Wall Panel: Exterior shall be manufacturers standard .032 Quaker Bronze, Austin White or Clear Anodized aluminum, 3” (76.2 mm) insulation and .032 interior aluminum of same color. Overall thickness of panel shall be 3” (76.2 mm).

Ceiling: Interior ceiling shall be foam core panel system providing smooth flat interior, constructed from 24 ga prefinished white steel with expanded polystyrene core.

Roof: Constructed using galvanized 20/24 ga., G-90 interlocking pan sections. Sections are 3” (76.2 mm) high varying widths able to support minimum 50/40 psf (1915 Pa) live load. Roof drains into full perimeter gutter system.

Windows: Fixed windows shall be single pane 1/8" (3.18 mm) clear tempered safety glass. Sliding windows shall have aluminum frame and 1/8" (3.18mm) clear tempered safety glass, insect screen, and locking device. Glass shall be glazed within wall system extrusions and not fastened to exterior wall. Glass sealed with concealed gasket system.

Door: Sliding door shall be extruded aluminum frame, top hung style using heavy duty ball bearing nylon tire with steel hub. Door shall be supplied with jimmy-proof single cylinder deadlock.

Electrical: Electrical shall be wired according to N.E.C. Standards. Load center shall be a 125 Amp, 120/240 volt unit with 8/16 open circuits. Wiring shall be within surface mounted EMT conduit.(1) GFCI duplex receptacle with tester is used as an outlet.

Lighting: (Quantity dependent on size of building) ceiling-mounted fluorescent light fixture(s), 48 inches (1200 mm) long and two 40-W lamps. Provide single-pole switch mounted adjacent to door to control lighting fixture.

 

Sample Specifications for Steel Buildings

 

Frame: Framing shall be 14 ga. (1.78 mm) or heavier mechanical tube.  All joints shall be MIG welded.

Base/Floor: Building to be typically constructed on a 4” mechanical tube frame. Floor surface to be 3/16” aluminum tread plate finished floor.

Wall Panels: Wall panels shall be 16 ga. exterior, 2” (50.8 mm) or 3” (76.2 mm) depending on wall thickness, E.P.S. insulation (2” R-10 or 3” R-12), and a 16 ga. inside face. Panels shall be galvanized and shall be MIG welded into place.

Ceiling: Interior ceiling shall be foam core panel system providing smooth flat interior. Constructed from 24 ga prefinished white steel with expanded polystyrene core.

Roof: Constructed using galvanized 20/24 ga., G-90 interlocking pan sections.  Sections are 3” (76.2 mm) high varying widths able to support minimum 50/40 psf (1915 Pa) live load. Roof drains into full perimeter gutter system.

Finish: Surfaces shall be painted using an epoxy/urethane prime to paint system designed to withstand salt spray and freeze thaw testing.

Windows: Fixed windows shall be 1/8" (3.18 mm) clear tempered safety glass. Sliding and cashier windows shall be 1/8" (3.18 mm) clear tempered safety glass. Window frames shall be anodized aluminum. Moving windows shall be supplied with insect screen and locking device.

Door: Sliding door shall be extruded aluminum frame, top hung style using an overhead track and heavy duty ball bearing nylon tires with steel hub. Door shall be supplied with mortise lock and hook bolt.

Electrical: Electrical shall be wired according to N.E.C. Standards. Load center shall be a 125 Amp, 120/240 volt unit with 8/16 open circuits. Wiring shall be within surface mounted EMT conduit. (1) GFCI duplex receptacle with tester is used as an outlet.

Lighting: (Quantity, dependent on size of building) ceiling-mounted fluorescent light fixture(s), 48 inches (1200 mm) long and two 40-W lamps. Provide single-pole switch mounted adjacent to door to control lighting fixture.


 

Both aluminum and steel construction guard booths offer an extensive range of options & extras (including bullet resistance, restrooms, heat, air conditioning, transaction extras, and more).

K-Con guard booths can be permanent or portable - or even trailer mounted.  K-Con offers both standard models and custom designs, while providing a wide assortment of standard and optional equipment.

K-CON’s booths fulfill your security needs and still remain architecturally pleasing.

 

Our guard booths are completely pre-fabricated and require no assembly by the customer.

 

No matter how basic or how custom your requirements, no matter what options are required, no matter your level of security requirements, K-CON is here to fulfill your perimeter security needs.


 Bullet Resistance Ratings Minimize
    
 ..  ....     

metal buildings maintenance and workshops

 

metal buildings training facilities

 

metal buildings warehouses and storage

  metal buildings security guard
 

metal buildings office

 

metal buildings renovation

 

metal buildings specialized

 

metal buildings residential

 

  

 

You must be a registered user with a military or federal email address to register and view GSA pricing.